Where is your area located?

Place the pin in the center of your area on the map...

...or enter the values manually.

What year?

Choose what year to use historical data from in the calculation.

(Only 2023 available in demo version)

Agri-OptiCE® uses data from the Copernicus Climate Change Service (C3S), including ERA5 reanalysis data. Data is either generated using C3S or contains modified information from it. Neither the European Commission nor ECMWF is responsible for any use that may be made of the Copernicus information or data it contains.

Copernicus Climate Change Service (2025): ERA5 hourly time-series data on single levels from 1940 to present. Copernicus Climate Change Service (C3S) Climate Data Store (CDS). Available from the CDS dataset catalogue.

What is your Albedo?

Albedo is the reflection from ground and crops to PV modules.

(Only fixed albedo values are available in demo version)

0 1

Example values:
Grass: 0.15 - 0.25  |  Fresh snow: 0.82  |  Bare soil: 0.05 - 0.17  |  Winter cereals: 0.05 - 0.32

What system type?

Choose fixed or dynamic system type.

(In the free version of Agri-OptiCE®, users can only select fixed agrivoltaic system.)

System Type: Fixed

Agri-OptiCE® simulates a representative section of your agrivoltaic project. To account for inter-row shading effects, please select multiple rows. In this version, simulations are limited to a maximum of 6 rows with a row length of up to 50 m.

Enter the values needed.

°
°
m
m
pc
m
m
pc

System Type: Dynamic

Agri-OptiCE® simulates a representative section of your agrivoltaic project. To account for inter-row shading effects, please select multiple rows. In this version, simulations are limited to a maximum of 6 rows with a row length of up to 50 m.

Enter the values needed.

°
°
m
m
m
pc
m
m
pc

PV System and Inverter

The default values on this page refer to the following PV module: JA Solar JAM72D40-600/MB.

Enter the values needed.

The energy conversion efficiency of the PV module at Standard Test Conditions.

%

μVoc refers to the temperature coefficient of open-circuit voltage.

%/°C

Vmp is the voltage at maximum power point of the single PV module.

V

NOCT refers to the Nominal Operating Cell Temperature.

°C

PV module area is the area of the single PV module.

Maximum output power a PV module delivers at Standard Test Conditions.

Wp

Bifaciality factor quantifies the relative efficiency of the rear side of a bifacial PV module compared to its front side, under Standard Test Conditions. The bifaciality factor should be a number between 0-1.

n/a

Power conversion efficiency of the inverter

%

What is your Crop?

(In the free version of Agri-OptiCE®, users can only select Alfalfa as crop.)

Example: If wheat is sown on 1 November, please enter 305 (for a non-leap year), corresponding to the day of the year of the planting date.

Planting date is the day of the year at which the crop is sown.

day
Example: If wheat is sown on 1 November (day 305 of the year) and harvested on 1 June of the following year (day 152 of the year), please enter 212 days. This value corresponds to the total growing season length, calculated as the sum of:
  • the days from 1 November to 31 December (61 days), and
  • the days from 1 January to 1 June (151 days).
Therefore: 61 + 151 = 212 days

Growing season is the number of days between sown and harvest.

day

What is your Soil type?

(In the free version of Agri-OptiCE®, users can only select Sand as soil.)

Result

Enter your details and e-mail address. We will send you the report as soon as it's ready.

(Please note that the time required to generate and receive the report depends on the current server load. In addition, the Agri-OptiCE® free trial limits automated report generation to a maximum of 10 reports per week per email account)

Please note that emails sent by the website may occasionally be delivered to your spam or junk folder. If you do not receive a message, please check those folders as well.

Check your inbox

We sent a 6-digit verification code to . Enter it below to confirm your submission.

Thank you!

Your data has been received. The result will be sent to .

Something went wrong

An error occurred. Please try again.